RHC-R
RELATIVE HUMIDITY CONTROLLER (with remote sensor)
Same as the RHC-1 except with the added feature of a 20 ft. remote sensor which is quite handy for those applications where sampling is necessary in a specific zone, or the area is inaccessible or for very small enclosures.
The RHC-R Relative Humidity Controller is our most recent development in total humidity control. It is switchable between humidify and dehumidify. The RHC-R has a built- in onboard sensor which is accurate within +/- 3% with a set differential of 5%. Perfect for plant zone environments, reptile habitats, or just about any application requiring accurate response and control.
Plug your humidity equipment into the 120 volt 3 prong piggy-back cord.
The RHC controller is universal and will work with 120v, 220v, or 240v - 50 or 60 hz automatically.
EXPLANATION OF OPERATION:
Here is an explanation of how this controller is programmed to perform. It has a dead ban (differential or hysteresis as you prefer) of 5%. This is the amount of humidity it will correct between coming On and going Off.
Dehumidifying mode: if your setpoint is 50% the controller will come On at 55% and bring the humidity back down to your desired 50% setpoint. So that is a 5% allowance above your optimum setting.
Humidifying mode: if your setpoint is 50% the controller will come on at 45% and raise your humidity to your setpoint of 50%.
Specifications:
• Humidity Range: 5-95% RH
• Humidity Differential: 5% RH
• Operating Temperature: 32-120ºF (0-50ºC)
• Operating Humidity: Non-Condensing Environment (0-95% RH)
• Voltage Input: 120 VAC
• Voltage Output: 120 VAC
• Max Amperage Rating: 15 AMPS
• Frequency: 60 Hz
• Dimensions: 4” Wide x 5-7/8” High x 2¼” Deep (10cm x 15cm x 6cm)
• Power Cord: 6-ft, piggy-back 14 awg, SJTW rated
• External Sensor Connection (if used): Std RJ-11 patchcord
The controller is to be connected by a standard 115 VAC NEMA 5-15 plug and socket. Units may have an optional plug in sensor or an integral sensor. The controller is enclosed in a corrosion proof anodized aluminum enclosure. The enclosure is capable of being wall mounted. The controller has power and on indicators. The control has a switch to select humidify and dehumidify functions.
TYPE OF CONTROL: The control may be switched between Open on Humidity Rise (Humidify) to Open on Humidity Fall (Dehumidify). The output is energized until the sensed humidity reaches the setpoint.
SETPOINT: The adjustable setpoint is the off point for either mode. The setpoint is adjustable by a knob over a 0-100% RH range. The differential between the on and off points is fixed at 5% RH.
INDICATORS: Power on is indicated by a red indicator. The output power is indicated by a green indicator.
STORAGE TEMPERATURE: -40 to 120 F.
OPERATING TEMPERATURE: 40 to 110 F.
HUMIDITY: 5 to 95% RH, non condensing.
ENCLOSURE SEALING: NEMA 1 enclosure, not sealed to moisture. Control, and sensor, must be protected from chemical or water sprays.
INPUT CONNECTION: Standard three wire NEMA 5-15P cordset.
INPUT POWER: 120 VAC, 15 A., 50/60 Hz.
OUTPUT CONNECTION: Integral NEMA 5-15R socket.
OUTPUT POWER: 120 VAC, 15 A., 1/2 Hp
EXTERNAL SENSOR: External sensor wiring is low voltage isolated signals.
Connections by standard RJ-12 crossover
Payment can be also made over the phone via Visa, Mastercard, American Express or Discover by calling 239-357-1853 Craig.
Weight: 3.00 lbs
RHC-R
RELATIVE HUMIDITY CONTROLLER (with remote sensor)
Same as the RHC-1 except with the added feature of a 20 ft. remote sensor which is quite handy for those applications where sampling is necessary in a specific zone, or the area is inaccessible or for very small enclosures.
The RHC-R Relative Humidity Controller is our most recent development in total humidity control. It is switchable between humidify and dehumidify. The RHC-R has a built- in onboard sensor which is accurate within +/- 3% with a set differential of 5%. Perfect for plant zone environments, reptile habitats, or just about any application requiring accurate response and control.
Plug your humidity equipment into the 120 volt 3 prong piggy-back cord.
The RHC controller is universal and will work with 120v, 220v, or 240v - 50 or 60 hz automatically.
EXPLANATION OF OPERATION:
Here is an explanation of how this controller is programmed to perform. It has a dead ban (differential or hysteresis as you prefer) of 5%. This is the amount of humidity it will correct between coming On and going Off.
Dehumidifying mode: if your setpoint is 50% the controller will come On at 55% and bring the humidity back down to your desired 50% setpoint. So that is a 5% allowance above your optimum setting.
Humidifying mode: if your setpoint is 50% the controller will come on at 45% and raise your humidity to your setpoint of 50%.
Specifications:
• Humidity Range: 5-95% RH
• Humidity Differential: 5% RH
• Operating Temperature: 32-120ºF (0-50ºC)
• Operating Humidity: Non-Condensing Environment (0-95% RH)
• Voltage Input: 120 VAC
• Voltage Output: 120 VAC
• Max Amperage Rating: 15 AMPS
• Frequency: 60 Hz
• Dimensions: 4” Wide x 5-7/8” High x 2¼” Deep (10cm x 15cm x 6cm)
• Power Cord: 6-ft, piggy-back 14 awg, SJTW rated
• External Sensor Connection (if used): Std RJ-11 patchcord
The controller is to be connected by a standard 115 VAC NEMA 5-15 plug and socket. Units may have an optional plug in sensor or an integral sensor. The controller is enclosed in a corrosion proof anodized aluminum enclosure. The enclosure is capable of being wall mounted. The controller has power and on indicators. The control has a switch to select humidify and dehumidify functions.
TYPE OF CONTROL: The control may be switched between Open on Humidity Rise (Humidify) to Open on Humidity Fall (Dehumidify). The output is energized until the sensed humidity reaches the setpoint.
SETPOINT: The adjustable setpoint is the off point for either mode. The setpoint is adjustable by a knob over a 0-100% RH range. The differential between the on and off points is fixed at 5% RH.
INDICATORS: Power on is indicated by a red indicator. The output power is indicated by a green indicator.
STORAGE TEMPERATURE: -40 to 120 F.
OPERATING TEMPERATURE: 40 to 110 F.
HUMIDITY: 5 to 95% RH, non condensing.
ENCLOSURE SEALING: NEMA 1 enclosure, not sealed to moisture. Control, and sensor, must be protected from chemical or water sprays.
INPUT CONNECTION: Standard three wire NEMA 5-15P cordset.
INPUT POWER: 120 VAC, 15 A., 50/60 Hz.
OUTPUT CONNECTION: Integral NEMA 5-15R socket.
OUTPUT POWER: 120 VAC, 15 A., 1/2 Hp
EXTERNAL SENSOR: External sensor wiring is low voltage isolated signals.
Connections by standard RJ-12 crossover
Payment can be also made over the phone via Visa, Mastercard, American Express or Discover by calling 239-357-1853 Craig.
- Brand Green Air
- Mfg Part # RHC-R
Payment Methods
Shipping
UPS, $15.00
Return/Exchange Policy
Return Policy.
A Return Goods Authorization (RGA) number must be obtained from customer service (1-239-357-1853). Products must be unused and in their original cartons. No discontinued or obsolete items will be accepted. For safety reasons, no returns can be accepted on HEPA items. Customer pays return freight charges and 15% restocking fee, except when return is due to freight damage. We reserves the right to refuse any return not in compliance with the above.
Please Login or Register first before asking a question.