vedardalarm"s Store > Fire Alarm System

Conventional fire alarm repeater panel 16 zones alarm display

Add to Cart
Shop conventional fire alarm system at https://www.vedardsecurity.com/16-zones-conventional-fire-alarm-repeater-panel-p-74 Conventional fire alarm zone display and operation with silence test. With RS485 to connect with other fire alarm and fire supervision device. Fire floor display and repeat panels have the following key features: 16 conventional repeater display zones. Fire alarm output relay and 1 fault output relay . Fire alarm output with 24VDC. RS485 can be able to connect the other panel. You can download the complete fire alarm system category and installation instruction manual fire alarm installation Specifications Power supply: 16VDC to 30VDC Current of power: Standby current: ≤15mA, Alarm current: ≤75mA Relay contact capacity: 2A@24VDC Buzzer level: 80dB@1m. Protection level: IP55 Communication mode:RS485 (Wires: RVSP type,1.0MM2 to 2.0MM2) Dimension of enclosure: 200mm(W)*91mm(H)*45mm(D) Material of enclosure:ABS, White Weight: 350g. Hole of enter wires: 1/2 inch(12mm) Repeater status indication and button operation FIRE ALARM Status: When a fire alarm occurs, the corresponding zone red LED flashing and the internal buzzer sounds. When “Silence” button pushed, the alarm zone LED lights steady and the buzzer silenced. When another new fire alarm occurs, the new zone red LED flash and the buzzer sound again. In the fire alarm status, the fire alarm “FIRE OUT” relay active and output “NO, NC, C” relay contacts and 24vdc power output. FAULT Status: When a fault event occurs, the corresponding zone’s yellow LED flashing and the internal buzzer sounds. When “Silence” button pushed, the fault zone LED lights steady and the buzzer silenced. When another new fault event occurs, the new zone yellow LED flash and the buzzer sound again. In the fault alarm status, the fault alarm “FAULT OUT” relay active and output “NO, NC, C” relay contacts. Normal status: When fire alarm panel’s fire or fault event restored, the fire alarm panel would send commands to let the repeater to the Normal Status. RUN LED: The “RUN” LED would keep light steady when the power supply in normal status. COMM. LED: The “COMM.” LED would flash once about three to five seconds in normal communication status. SILENCE LED: In the fire or fault alarm status, press the “Silence” button the “SILENCE” LED would turn on . TEST LAMP: In normal status, press “TEST” button would have a lamp test. SILENCE SOUND: In fire or fault status, press “SILENCE” button would silence the alarm sound. RESET: In the “SILENCE” status,press “RESET” button once the repeater would return to the Normal Status.
    • UPC 757158647631
    • Brand TC
    • Mfg Part # RP-1016
Payment Methods
Shipping FEDEX

 
Zip or postal code:
  • FedEx Shipping Rates
  • FedEx Ground

Payment Policy

Conditions of use

Hello and welcome to Vedard Alarm Systems Store. When you visit or shop at our alarm systems online store, you agree to these conditions.

Vedard Alarm Systems Company attempts to make product descriptions as accurate as possible. However, Vedard does not warrant that product descriptions are complete, current or error-free. If there is any doubts, please feel free to send email to check with us before buying.

Alarm Systems are devices of installation required before using. So, please make sure there is experienced alarm installer, electronic engineer, security service or experienced alarm user for the installation work after item is bought.

Vedard is not responsible for any wrong purchasing, non working of product with wrong configuration. Please make sure the wireless compatibility of buying wireless alarm accessories, wireless sensor with your exist wireless alarm system.

Cause of high rate international shipping charge for you and us, we do not accept fault goods return. But we offer 50% off new one sales for compensation. Product fault evidence is required.

You are welcome to post alarm systems reviews, comments on our website for your purchased products. And you are welcome to leave us a review at third party home security review website at home security reviews

Please make sure the content you posted is accurate, truthful and detailed to help visitors understanding our products and service well. Vedardalarm.com has the right to monitor and edit or remove any activity or content.

Shipping Policy

Thanks for shopping alarm systems at Vedard Alarm Systems Store.

Preparation for delivery usually takes 3~7 business days.

Generally, DHL shipping service is used for delivery and delivery time is 3~5 business days for most countries.

For package weight less than 2kgs, we may use air post service for delivery and delivery time may be 15~25 days.

Once an order was shipped, you will receive an email with tracking information.

Low customs value will be made to reduce your import tax in our commercial invoice.

If you have special requirement for shipping, please leave comment with us when you place the order. Thank you!

We can send email of alarm system manual for your preparing installing new technology alarm systems. Please contact us to send the alarm system manual.

If your ordered goods is happened out of stock or not available to be shipped, we will issue 100% refund immediately and send email notice to you.

Tracking No. will be provided.

We may use DHL, EMS, China post air mail, Swiss post air mail to deliver your parcel.

The parcel tracking Website is as below:

DHL

China post air mail

EMS

Swiss post air mail

Return/Exchange Policy

Your benefit is guaranteed while shopping at Vedard Security Systems Store.

We will refund you product rate once product shipped is found with fault.

But video, photo evidence should be provided and confirmed by our technical department. Refund application should be submitted within 7 days after products received. Refund application should be sent to service@vedardalarm.com and title with Refund order #.

Buyers are requested to read and know product carefully before buying. And you can ask question via our forum or e-mail. We don't accept wrong buying refund.

Buyer can select to return to us with product rate and freight rate refund. But return cost is charged by buyer.

Other Policies

Household alarms should be as necessary as household appliances. But home alarms are special products.It plays an important role in keeping the family safe.Therefore, the installation and use of family alarm should be based on the home environment safety needs and alarm installation requirements. For wireless alarm, different manufacturers, different brands of alarm equipment is not compatible. Therefore, before buying an alarm, carefully read the product description and understand the brand of the product to determine its wireless compatibility.
There are many kinds of alarms. Alarm manufacturers designed a variety of alarms for different users of different habits or environmental differences. Therefore, you can choose the most appropriate alarm according to your own security needs.
Before buying alarm equipment, you should understand the functions and characteristics of all kinds of alarms and your own security needs. If you have any questions, please contact the product seller. Professional alarm equipment sales will provide detailed product installation instructions, video demonstrations, and technical guidance.
The products details and technical support for vedardalarm security can be found at https://www.vedard.com/forum

Please Login or Register first before asking a question.
More from vedardalarm's Store