OWON XDM3041 Benchtop Digital Multimeter - True RMS - 4 1/2 Digit Resolution
Overview:
- 4 inch 480 x 320 pixels high resolution LCD
- Resolutions up to 4 1/2 digits
- Reading rates up to 150 readings/s
- True RMS AC voltage / current measurement
- Dual line display supported
- SCPI supported - remote control, and data-sharing possible via LAN, USB, RS232 port, and WiFi* (WiFi module is optional)
- Multi- IO interface: USB Device / Host, RS232, LAN, and ext. trigger input
- Change trend analysis via chart mode
- Data Logger Mode - set logging duration, length, and charting capabilities
OWON XDM3041 Benchtop Digital Multimeter Specifications:
DC Voltage:
Measurement Range - 600mV, 6V, 60V, 600V, 1000V
Frequency Range - N/A
Accuracy: 1 Year ± (% of reading +% of range) - 0.02±0.01
True RMS AC Voltage:
Measurement Range – 600mV, 6V, 60V, 600V, 750V
Frequency Range / Accuracy: 1 Year ± (% of reading +% of range) - 0.02±0.01
- 20 Hz - 50 Hz / 2 + 0.10
- 50 Hz - 20 kHz / 0.2 + 0.06
- 20 kHz - 50 kHz / 1.0 + 0.05
- 50 kHz - 100 kHz / 3.0 + 0.08
DC Current (Frequency Range – N/A):
Measurement Range / Accuracy: 1 Year ± (% of reading +% of range) - 0.02±0.01
- 600.00 μA / 0.06 + 0.02
- 6.0000 mA / 0.06 + 0.02
- 60.000 mA / 0.1 + 0.05
- 600.00 mA / 0.2 + 0.02
- 6.000 A / 0.2 + 0.05
- 10.0000 A / 0.250 + 0.05
True RMS AC Current:
Measurement Range - 60.000 mA, 600.00 mA, 6.0000 A, 10.000 A
Frequency Range / Accuracy: 1 Year ± (% of reading +% of range) - 0.02±0.01
- 20 Hz - 45 Hz / 2 + 0.10
- 45 Hz - 2 kHz / 0.50 + 0.10
- 2 kHz - 10 kHz / 2.50 + 0.20
Resistance (Frequency Range N/A):
Measurement Range / Accuracy: 1 Year ± (% of reading +% of range) - 0.02±0.01
- 600.00 Ω / 0.040 + 0.01
- 6.0000 kΩ / 0.030 + 0.01
- 60.000 kΩ / 0.030 + 0.01
- 600.00 kΩ / 0.040 + 0.01
- 6.0000 MΩ / 0.120 + 0.03
- 60.000 MΩ / 0.90 + 0.03
- 100.00 MΩ / 1.75 + 0.03
Diode Test (Frequency Range N/A):
- 3.0000 V / 0.5 + 0.01
Continuity (Frequency Range N/A):
- 1000 Ω / 0.5 + 0.01
Frequency Period:
Measurement Range - 200 mV - 750 V
Frequency Range / Accuracy: 1 Year ± (% of reading +% of range) - 0.02±0.01
- 20 Hz - 2 kHz / 0.01 + 0.003
- 2 kHz - 20 kHz / 0.01 + 0.003
- 20 kHz - 200 kHz / 0.01 + 0.003
- 200 kHz - 1 MHz / 0.01 + 0.006
Measurement Range - 20 mA - 10 A
Frequency Range / Accuracy: 1 Year ± (% of reading +% of range) - 0.02±0.01
- 20 Hz - 2 kHz / 0.01 + 0.003
- 2 kHz - 10 kHz / 0.01 + 0.003
Capacitance:
Measurement Range - 2.000 nF
Test Current - 200 nA
Accuracy: 1 Year ± (% of reading +% of range) - 3 + 1.0
Measurement Range - 20.00 nF
Test Current - 200 nA
Accuracy: 1 Year ± (% of reading +% of range) - 1 + 0.5
Measurement Range - 200.0 nF
Test Current - 2 μA
Accuracy: 1 Year ± (% of reading +% of range) - 1 + 0.5
Measurement Range - 2.000 μF
Test Current - 10 μA
Accuracy: 1 Year ± (% of reading +% of range) - 1 + 0.5
Measurement Range - 200 μF
Test Current - 100 μA
Accuracy: 1 Year ± (% of reading +% of range) - 1 + 0.5
Measurement Range - 10000 μF
Test Current - 1 mA
Accuracy: 1 Year ± (% of reading +% of range) - 2 + 0.5
Temperature:
- temperature sensors under 2 categories supported -
- thermocouple (ITS-90 conversion between B / E / J / K / N / R / S / T type), and thermal resistance (RTD sensor con-version between Pt100 and Pt385 type)
Other functions:
Bar meter, histogram, trend chart, Max. Min. value, average value, standard deviation,
DB / DBm, Pass / Fail
Data-logger Function:
Logging Duration - 5ms
Logging Length - 1M points
General:
Dimension (W x H x D) - 235 x 110 x 295 (mm)
Weight (without package) - 3.0 kg
Accessories Included:
Power Cord, Manual, USB Cord, Fuse, Multimeter Lead, Alligator Clips
Overview:
- 4 inch 480 x 320 pixels high resolution LCD
- Resolutions up to 4 1/2 digits
- Reading rates up to 150 readings/s
- True RMS AC voltage / current measurement
- Dual line display supported
- SCPI supported - remote control, and data-sharing possible via LAN, USB, RS232 port, and WiFi* (WiFi module is optional)
- Multi- IO interface: USB Device / Host, RS232, LAN, and ext. trigger input
- Change trend analysis via chart mode
- Data Logger Mode - set logging duration, length, and charting capabilities
OWON XDM3041 Benchtop Digital Multimeter Specifications:
DC Voltage:
Measurement Range - 600mV, 6V, 60V, 600V, 1000V
Frequency Range - N/A
Accuracy: 1 Year ± (% of reading +% of range) - 0.02±0.01
True RMS AC Voltage:
Measurement Range – 600mV, 6V, 60V, 600V, 750V
Frequency Range / Accuracy: 1 Year ± (% of reading +% of range) - 0.02±0.01
- 20 Hz - 50 Hz / 2 + 0.10
- 50 Hz - 20 kHz / 0.2 + 0.06
- 20 kHz - 50 kHz / 1.0 + 0.05
- 50 kHz - 100 kHz / 3.0 + 0.08
DC Current (Frequency Range – N/A):
Measurement Range / Accuracy: 1 Year ± (% of reading +% of range) - 0.02±0.01
- 600.00 μA / 0.06 + 0.02
- 6.0000 mA / 0.06 + 0.02
- 60.000 mA / 0.1 + 0.05
- 600.00 mA / 0.2 + 0.02
- 6.000 A / 0.2 + 0.05
- 10.0000 A / 0.250 + 0.05
True RMS AC Current:
Measurement Range - 60.000 mA, 600.00 mA, 6.0000 A, 10.000 A
Frequency Range / Accuracy: 1 Year ± (% of reading +% of range) - 0.02±0.01
- 20 Hz - 45 Hz / 2 + 0.10
- 45 Hz - 2 kHz / 0.50 + 0.10
- 2 kHz - 10 kHz / 2.50 + 0.20
Resistance (Frequency Range N/A):
Measurement Range / Accuracy: 1 Year ± (% of reading +% of range) - 0.02±0.01
- 600.00 Ω / 0.040 + 0.01
- 6.0000 kΩ / 0.030 + 0.01
- 60.000 kΩ / 0.030 + 0.01
- 600.00 kΩ / 0.040 + 0.01
- 6.0000 MΩ / 0.120 + 0.03
- 60.000 MΩ / 0.90 + 0.03
- 100.00 MΩ / 1.75 + 0.03
Diode Test (Frequency Range N/A):
- 3.0000 V / 0.5 + 0.01
Continuity (Frequency Range N/A):
- 1000 Ω / 0.5 + 0.01
Frequency Period:
Measurement Range - 200 mV - 750 V
Frequency Range / Accuracy: 1 Year ± (% of reading +% of range) - 0.02±0.01
- 20 Hz - 2 kHz / 0.01 + 0.003
- 2 kHz - 20 kHz / 0.01 + 0.003
- 20 kHz - 200 kHz / 0.01 + 0.003
- 200 kHz - 1 MHz / 0.01 + 0.006
Measurement Range - 20 mA - 10 A
Frequency Range / Accuracy: 1 Year ± (% of reading +% of range) - 0.02±0.01
- 20 Hz - 2 kHz / 0.01 + 0.003
- 2 kHz - 10 kHz / 0.01 + 0.003
Capacitance:
Measurement Range - 2.000 nF
Test Current - 200 nA
Accuracy: 1 Year ± (% of reading +% of range) - 3 + 1.0
Measurement Range - 20.00 nF
Test Current - 200 nA
Accuracy: 1 Year ± (% of reading +% of range) - 1 + 0.5
Measurement Range - 200.0 nF
Test Current - 2 μA
Accuracy: 1 Year ± (% of reading +% of range) - 1 + 0.5
Measurement Range - 2.000 μF
Test Current - 10 μA
Accuracy: 1 Year ± (% of reading +% of range) - 1 + 0.5
Measurement Range - 200 μF
Test Current - 100 μA
Accuracy: 1 Year ± (% of reading +% of range) - 1 + 0.5
Measurement Range - 10000 μF
Test Current - 1 mA
Accuracy: 1 Year ± (% of reading +% of range) - 2 + 0.5
Temperature:
- temperature sensors under 2 categories supported -
- thermocouple (ITS-90 conversion between B / E / J / K / N / R / S / T type), and thermal resistance (RTD sensor con-version between Pt100 and Pt385 type)
Other functions:
Bar meter, histogram, trend chart, Max. Min. value, average value, standard deviation,
DB / DBm, Pass / Fail
Data-logger Function:
Logging Duration - 5ms
Logging Length - 1M points
General:
Dimension (W x H x D) - 235 x 110 x 295 (mm)
Weight (without package) - 3.0 kg
Accessories Included:
Power Cord, Manual, USB Cord, Fuse, Multimeter Lead, Alligator Clips
- Brand OWON
- Mfg Part # XDM3041
Payment Methods
Shipping
UPS, FREE Shipping
Please Login or Register first before asking a question.